Seleccione su país

Visite el sitio web global

EPV-6100-MPM-* 6100 Series Mini Vent

Ventajas clave de un vistazo

  • Flow rate: 2,000 ... 6,000 l/min
  • Intrinsically safe when connected to 6100 control unit
  • Compact footprint
Product Compliance: Europe – CE
Approval
Nota

Todos los documentos relacionados con los productos, como certificados, declaraciones de conformidad, etc., que se emitieron antes de la conversión con el nombre de Pepperl+Fuchs GmbH o Pepperl+Fuchs AG también se aplican a Pepperl+Fuchs SE.

EN
  • EN
  • DE

Datos técnicos de EPV-6100-MPM-*

6100 series purge and pressurization enclosure protection mini vent
Series6100 Series
SystemEx pxb Purge
Hazardous environmentgas
Connection
PowerIntrinsically safe connection to the 6100 control unit
Signal2-wire intrinsically safe pressure switch
Connection2-wire
Protective gas supplyClean air or inert gas
Safe pressure0.625 mbar [0.25 in wc / 6.4 mm wc)
Enclosure pressure0 ... 50 mbar (0 ... 20.1 in wc / 0 ... 510.5 mm wc)
Flow rate for leakage compensationdepends on enclosure seal
based on completely sealed enclosure
Breaking pressureApprox. 10 mbar (4.0 in wc)
Approx. 15 mbar (6.0 in wc)
Approx. 20 mbar (8.0 in wc)
Approx. 30 mbar (12.1 in wc)
Approx. 40 mbar (16.1 in wc)
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
RoHS
Directive 2011/65/EU (RoHS)EN 50581:2012
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-20 ... 80 °C (-4 ... 176 °F)
Relative humidity5 ... 95 %, noncondensing
Vibration resistanceEN 60068-2-6
Impact resistanceEN 60068-2-27
Material316L stainless steel (housing)
Installation-gravity dependent
-air outlet, screen side must be facing down
Mass9 kg (20 lb)
CertificateCML 19 ATEX 1425X
MarkingEx-Hexagon II2G Ex db eb ib [ib Gb][pxb Gb] IIC T4 Gb
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018
EN 60079-1:2014
EN 60079-2:2014
EN 60079-7:2015
EN 60079-11:2012
IECEx approvalIECEx CML 19.0156X
Ex db eb ib [ib Gb][pxb Gb] IIC T4 Gb
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Supplemental Standards : EN 61010-1:2010