Go to global website
Ultrasonic sensor with IO-Link interface in cubic design and 2 push-pull output, IO-Link Interface for process data, parameterization and diagnosis, Selectable sound lobe width, TEACH-IN, Series: UB-F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Interface type: IO-Link, Output type: 2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected, UL approval: cULus Listed, Class 2 Power Source
Ultrasonic sensor with IO-Link interface in cubic design and 1 push-pull output, IO-Link Interface for process data, parameterization and diagnosis, Selectable sound lobe width, TEACH-IN, Series: UB-F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Interface type: IO-Link, Output type: 1 push-pull output , short-circuit protected , reverse polarity protected, UL approval: cULus Listed, Class 2 Power Source
Single head system, IO-Link Interface for process data, parameterization and diagnosis, Programmable via DTM with PACTWARE, Programmable via IrDA (infrared interface), Series: UC-18GS, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Interface type: IO-Link (via C/Q = Pin 4), Interface type: IrDA (infrared interface), Output type: 2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected, UL approval: cULus Listed, Class 2 Power Source
Single head system, IO-Link Interface for process data, parameterization and diagnosis, Programmable via DTM with PACTWARE, Programmable via IrDA (infrared interface), Series: UC-18GS, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Interface type: IO-Link (via C/Q = Pin 4), Interface type: IrDA (infrared interface), Output type: 1 push-pull output , short-circuit protected , reverse polarity protected, Output type: 1 analog output 0 (4) ... 20 mA or , 1 analog output 0 ... 10 V
Ultrasonic system for reliable detection of no, one, or two overlapping sheet materials, Insensitive to printing, colors, and shining surfaces, Very wide material spectrum, finest papers up to thin sheet metals as well as plastic- and metal foils, Sensing range: 20 ... 60 mm , optimal distance: 45 mm, Thread mold: M18, Construction type: Cylindrical, thread, Series: UDC-18GM, Operating voltage: 18 ... 30 V DC , ripple 10 %SS, Interface type: IO-Link
Distance sensor, Medium design with versatile mounting options, Space-saving distance sensors in small standardized design, Multi Pixel Technology (MPT) - exact and precise signal evaluation, IO-Link interface for service and process data
Single head system, IO-Link interface for service and process data, Programmable via DTM with PACTWARE, Continuous distance value via IO-Link process data, Series: UC-F77, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Interface type: IO-Link (via C/Q = Pin 4), Output type: 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V
32-channel, 24 V DC supply, Interface for serial or parallel wiring options, Dual RS 485 connections, Slot for HART Multiplexer, Number of channels: 32 unbalanced signal loops
Ethernet IO-Link module with eight IO-Link ports
Interface for Power Rail, Used for redundant configuration, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication
Triangulation sensor with background suppression, Miniature design with versatile mounting options, Best background suppressor in its class, Precision object detection, almost irrespective of the color, Extended temperature range, -40 °C ... 60 °C, High degree of protection IP69K
Laser diffuse mode sensor with adjustable background suppression, Medium design with versatile mounting options, DuraBeam Laser Sensors - durable and employable like an LED, Extended temperature range, -40 °C ... 60 °C, High degree of protection IP69K, IO-Link interface for service and process data
Triangulation sensor with background suppression, Medium design with versatile mounting options, Best background suppressor in its class, Precision object detection, almost irrespective of the color, Extended temperature range, -40 °C ... 60 °C, High degree of protection IP69K
35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 2 m (6 foot), simple to customize to application space, Eliminates daisy-chains
AS-Interface power supply, data decoupling, 4 A
G11 module, 4 inputs
Fieldbus diagnostic handheld for comprehensive diagnostics of the fieldbus physical layer, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, Europe
Fieldbus power supply, module for fieldbus power hub, Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Advanced diagnostic module, plug-in module for the fieldbus power hub, Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada
32-channel, 24 V DC supply, HART field device input (revision 5 to 7), RS-485 interface, Up to SIL 3 acc. to IEC/EN 61508
IDENTControl Compact RFID evaluation unit with EtherCAT interface
I/O hub with IO-Link interface for 16 digital inputs
Ethernet IO module with 16 configurable digital inputs/outputs
1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as signal splitter (1 input and several outputs), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad, Housing width: 40 mm, Number of channels: 1-channel, HART communication, Trip relay, Rated voltage: 19 ... 30 V DC, Function: transmitter supply, Field device: 3-wire transmitter, Field device [2]: active sources, Signal: HART
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 18 ... 30 V DC
1-channel signal conditioner, 24 V DC supply (Power Rail), Scaleable current or voltage input, Current or voltage output, Relay contact output, Configurable by keypad, Line fault detection (LFD), Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 20 ... 30 V DC, Type: 1 x relay (change-over contact), Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x 0/1 ... 5 V, Signal [3]: 1 x 0/2 ... 10 V, Line fault detection
Fieldbus Power Supply, Output: 25 ... 27 V/360 mA, For most fieldbus applications, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk
Diffuse mode sensor, Medium design with versatile mounting options, Extended temperature range, -40 °C ... 60 °C, High degree of protection IP69K, IO-Link interface for service and process data
Diffuse mode sensor, Miniature design with versatile mounting options, Extended temperature range, -40 °C ... 60 °C, High degree of protection IP69K, IO-Link interface for service and process data
Retroreflective sensor with polarization filter, Medium design with versatile mounting options, Extended temperature range, -40 °C ... 60 °C, High degree of protection IP69K, IO-Link interface for service and process data
Retroreflective sensor with polarization filter, Miniature design with versatile mounting options, Extended temperature range, -40 °C ... 60 °C, High degree of protection IP69K, IO-Link interface for service and process data
Triangulation sensor with background suppression, Miniature design with versatile mounting options, DuraBeam Laser Sensors - durable and employable like an LED, Extended temperature range, -40 °C ... 60 °C, High degree of protection IP69K, IO-Link interface for service and process data
Laser diffuse mode sensor with adjustable background suppression, Miniature design with versatile mounting options, DuraBeam Laser Sensors - durable and employable like an LED, Extended temperature range, -40 °C ... 60 °C, High degree of protection IP69K, IO-Link interface for service and process data
Read head for incident light positioning system, EtherNet/IP, Non-contact positioning on Data Matrix code tape, Mechanically rugged: no wearing parts, long operating life, maintenance-free, High resolution and precise positioning, especially for facilities with curves and switch points as well as inclines and declines., Integrated switch, Travel ranges up to 10 km
Reed safety switch for non-contact AS-Interface safety switches
AS-Interface power supply, data decoupling, 8 A
AS-Interface advanced repeater with terminator
Actuator for non-contact AS-Interface Reed safety switch
AS-Interface module for stack light
KE3 control cabinet module, 4 inputs, 1 control-safe relay output
49 / 2731
Are you looking for more information? Feel free to learn more on our related pages.